Ingersoll Rand Starter Motors for Solar Turbines - ATEX Product Safety Information (10550663)

This manual sets out the ATEX product safety conditions for Ingersoll Rand starter motors supplied for Solar turbines and used in potentially explosive atmospheres. It explains the II 3 GD c IIB 71°C X marking, the special conditions for installation, operation and maintenance, the measured maximum surface temperature, and the recommended full-rebuild interval in start cycles for each covered model. It closes with the safety signal words and a Declaration of Conformity listing the models and standards; it is meant for turbine packagers, installers and maintenance staff.

Shop gas

Document at a Glance

Publisher
Ingersoll Rand
Document type
Safety information
Form / number
No. 10550663, Edition 2, February 2006
Language
English (Declaration of Conformity headings also in FR, DE, IT, ES, NL, DA, SV, NO, FI, PT, EL)
Pages
8
File
PDF, 313 KB

What's in This Document

SectionPagesWhat it covers
Solar Corporation Starter Motors Intended for use in Potentially Explosive Atmospheres2States the motors were reviewed against ATEX Directive 94/9/EC and that the marking applies to the starter motor, not the whole turbine.
Special Conditions for Safe Application, Installation, Operation and Maintenance2Warning topics: safe exhaust venting, friction and sparks, working only in a non-explosive atmosphere and using a work permit system.
Application and Installation3Limits use to starting Solar turbines or pre/post-lube and wet seal back-up pumping, excludes certain gases and requires grounding.
Starter Motor Operating Conditions3Covers rated pressure on the serial plate and the measured maximum surface temperature.
Maintenance3Maintenance topics and a table of recommended complete-rebuild intervals in start cycles for the ATEX models.
Explanation of ATEX Marking and Declaration of Incorporation4Decodes each element of the ATEX marking and explains the directive's intent.
Safety Symbol Identification / Explanation of Safety Signal Words5Protective equipment symbols and the meaning of DANGER, WARNING, CAUTION and NOTICE.
Declaration of Conformity6Multilingual declaration naming the models, directive 94/9/EC, the standards used and the February 2006 date.

Key Specifications and Data

From Ingersoll Rand Starter Motors for Solar Turbines - ATEX Product Safety Information (10550663)
ItemValuePage
ATEX markingII 3 GD c IIB 71° C X2
Equipment group / categoryGroup II (non-mine), Category 34
Gas groupIIB (covers Group A as well)4
Maximum surface temperature71°C at 21°C ambient; motor at free speed, 90 psig (6.2 bar / 620 kPa) inlet3
Required resistance to earthLess than 10000 Ohms3
Maximum air pressureRated pressure marked on the starter serial number plate3
Excluded gasesGroup C gases (acetylene, carbon disulfide, hydrogen), hydrogen sulfide, ethylene oxide, carbon monoxide3
ApplicationsStarting Solar turbines, or driving their pre/post-lube and wet seal back-up pumps; Solar turbines only3
Directive94/9/EC (ATEX); Machinery Directive 98/37/EC also cited4
Standards appliedEN 13463-1, EN 13463-5, EN 1127-1, EN 500146
Rebuild interval, TS14xx, TS725 and ST9xx models4000 start cycles3
Rebuild interval, 92RMG10 and 150RMG14C1000 start cycles3
Serial number range in declarationSPO6B onward6

Recommended complete-rebuild interval (gearing, bearings, etc.) for ATEX models

Page 3
Solar numberModelInterval
1070744-1201RM16/VRM-1722000 start cycles
1064469-192RMG101000 start cycles
1064470-1150RMG14C1000 start cycles
1071549-100201RM212000 start cycles
1065986-100 / -200 / -300 / -400TS1425 / TS1499 / TS1435 / TS14504000 start cycles
1070272-1MVA017B/VSM-58422000 start cycles
1070270-100SS1600/1329BA2000 start cycles
1070745-200TS725GBBE-LE4000 start cycles
1070745-100TS725GBDE-LE4000 start cycles
1065986-11ST925G-RC3504000 start cycles
1065986-15ST999G-RC3504000 start cycles
1065986-8ST935G-RC3504000 start cycles
1065986-17ST950GS-RC3504000 start cycles

Models Covered

Model codes as printed in the document. Linked codes go to the matching Ingersoll Rand starter in our catalog.

ST950GS-RC350 ST925G-RC350 ST935G-RC350 ST999G-RC350 TS725GBBE-LE TS725GBDE-LE TS1425 TS1435 TS1450 TS1499 SS1600/1329BA 201RM16/VRM-172 201RM21 150RMG14C 92RMG10 MVA017B/VSM-5842

Frequently Asked Questions

What does the ATEX marking II 3 GD c IIB 71°C X mean on these starter motors?

Per the manual: Group II non-mine equipment, Category 3, evaluated for gas (G) and dust (D) atmospheres, protection by constructional safety (c), gas group IIB, a 71°C maximum surface temperature, and X for special conditions that must be followed.

How often should an ATEX starter motor for a Solar turbine be rebuilt?

The manual recommends a complete rebuild every 1000, 2000 or 4000 start cycles depending on the model; for example, the TS1425 and ST925G-RC350 are listed at 4000 start cycles.

What surface temperature was measured on these starter motors?

A maximum of 71°C at 21°C ambient, with the motor at free speed on 90 psig (6.2 bar) inlet air.

Can these ATEX starters be used on equipment other than Solar turbines?

No. The document states the ATEX designation applies only to use on Solar turbines and the product is not for non-Solar applications.

What grounding is required for these starter motors?

The manual requires the motor to be grounded at all times with a resistance to earth below 10000 Ohms to avoid electrostatic discharge.

Need the parts or the starter in this document? Send the model number from your starter's plate and we will confirm the right Ingersoll Rand part or replacement.

Request a Quote 1-800-353-4676 Model Finder

Source: Ingersoll Rand, No. 10550663, Edition 2, February 2006. Summary and tables prepared by AirStartersDirect.com, an authorized Ingersoll Rand air starter distributor; the PDF is the authoritative version. Page numbers refer to the PDF file. Reviewed October 2026.







Turbine Air Starter Category Links



Ingersoll Rand ST150 Series Turbine Air Starters are designed for engines 13-95 liters and pack a powerful 47HP in a solid aluminum turbine motor based on the patented next generation technology from the rugged, long lasting, easy to service, high performing and efficient ST1000 turbine starter. Built to withstand the toughest environmental and working conditions – combining robust features and flexibility to deliver reliable, heavy-duty starting in a wide variety of industrial, oil and gas, marine, power generation, and mining applications.

ST150 Series

Updated turbine starter from Ingersoll Rand for engines from 16-95 liters.

Ingersoll Rand ST1000 Series air starters are built to withstand the toughest environmental and working conditions to deliver reliable, heavy-duty starting in a wide range of industrial, oil and gas, marine, power generation, rail, and mining applications. For engine displacement of: Diesel–1000 to 20,000 CID (16 to 320 liters) Carburated–2000

ST1000 Series

Powerful 70 hp turbine motor offers best-in-class performance in the harshest conditions!

Ingersoll Rand ST2000 Series air starters are built to withstand the toughest environmental and working conditions to deliver reliable, heavy-duty starting in a wide range of industrial, oil and gas, marine, power generation, rail, and mining applications. For engine displacement of 15 to 150 liters!

NEW ST2000 Series

NEWEST MODEL! Unlocks unprecedented productivity for engines ranging from 15 up to 150 liters!

For engine displacement of Diesel–300 to 3600 CID (5 to 60 liters) Carburated–1000 to 7200 CID (16 to 120 liters) Industry applications ideal for the ST400 Series starters - marine and power generation.

ST400 Series

 Industrial duty air starter for engines 5 to 60 liters (Diesel). Commonly used in marine, trucking, transit, and oil & gas applications.

For engine displacement of: Diesel–1000 to 5000 CID (16 to 80 liters) Carburated–2000 to 10,000 CID (32 to 160 liters) Industry applications ideal for the ST600 Series starter - mining and marine.

ST600 Series

  Industrial duty air starter for engines 16 to 80 liters (Diesel). Commonly used in mining and marine applications.

For engine displacement of: Diesel–1000 to 20,000 CID (16 to 320 liters) Carburated–2000 to 40,000 CID (32 to 660 liters) Industry applications for the ST700 and ST900 Series starters - oil and gas, marine, power-gen, and transportation.

ST700 / ST900 Series

 For engine displacement of: Diesel 16 to 320 liters Industry applications for the ST700 and ST900 Series starters - oil and gas, marine, power-gen, and transportation.

For engine displacement of Diesel–300 to 3600 CID (5 to 60 liters) Carburated–1000 to 7200 CID (16 to 120 liters) Industry applications ideal for the Ingersoll Rand 150T Series starters- marine, trucking, transit, oil and gas.

150T Series

Industrial duty air starter for engines 5 to 60 liters (Diesel). Commonly used in marine, trucking, transit, and oil & gas applications.






Vane Air Starter, Gas Turbine Starter, and Engine Barring Motor Category Links



One size fits engines up to 10+ liters to lower cost and reduce inventory

SS100 Series

NEW! One Size fits engines up to 10+ liters.

For engine displacement of: Diesel–500 to 2000 CID (8 to 32 liters) Carburated–1000 to 4000 CID (16 to 64 liters)

150BMP Series

For Diesel engines 8 - 32 liters.

Top quality Ingersoll Rand sealed starters for use with gas applications.

TS Series Gas Turbine

Sealed for Gas applications.

For engine displacement of: Diesel–200 to 1200 CID (3 to 20 liters) Carburated–400 to 2400

 SS175 / SS350 Series

For Diesel engines 3 to 20 liters.

For engine displacement of: Diesel–1000 to 20,000 CID (16 to 320 liters) Carburated–2000 to 40,000 CID (32 to 640 liters)

SS800 Series

For Diesel engines 16 - 320 liters.

Ingersoll-Rand offers the B006 Series and T480 Series pneumatic barring motors, making service work on diesel engines up to 500 liters and gas engines up to 1,000 liters easier and safer.

Engine Barring Motors

For service work on diesel engines.




Questions? Need Help Finding The Right air Starter? Use Our Fast Response Form Below

Click Here to get an air starter quote FAST!

Or Call Us at 1-800-353-4676


Not sure which starter fits your engine?

Tell us the engine make and model and we’ll match the right Ingersoll Rand starter.