Ingersoll Rand literature · Safety information
Ingersoll Rand Starter Motors for Solar Turbines - ATEX Product Safety Information (10550663)
This manual sets out the ATEX product safety conditions for Ingersoll Rand starter motors supplied for Solar turbines and used in potentially explosive atmospheres. It explains the II 3 GD c IIB 71°C X marking, the special conditions for installation, operation and maintenance, the measured maximum surface temperature, and the recommended full-rebuild interval in start cycles for each covered model. It closes with the safety signal words and a Declaration of Conformity listing the models and standards; it is meant for turbine packagers, installers and maintenance staff.
Document at a Glance
- Publisher
- Ingersoll Rand
- Document type
- Safety information
- Form / number
- No. 10550663, Edition 2, February 2006
- Language
- English (Declaration of Conformity headings also in FR, DE, IT, ES, NL, DA, SV, NO, FI, PT, EL)
- Pages
- 8
- File
- PDF, 313 KB
What's in This Document
| Section | Pages | What it covers |
|---|---|---|
| Solar Corporation Starter Motors Intended for use in Potentially Explosive Atmospheres | 2 | States the motors were reviewed against ATEX Directive 94/9/EC and that the marking applies to the starter motor, not the whole turbine. |
| Special Conditions for Safe Application, Installation, Operation and Maintenance | 2 | Warning topics: safe exhaust venting, friction and sparks, working only in a non-explosive atmosphere and using a work permit system. |
| Application and Installation | 3 | Limits use to starting Solar turbines or pre/post-lube and wet seal back-up pumping, excludes certain gases and requires grounding. |
| Starter Motor Operating Conditions | 3 | Covers rated pressure on the serial plate and the measured maximum surface temperature. |
| Maintenance | 3 | Maintenance topics and a table of recommended complete-rebuild intervals in start cycles for the ATEX models. |
| Explanation of ATEX Marking and Declaration of Incorporation | 4 | Decodes each element of the ATEX marking and explains the directive's intent. |
| Safety Symbol Identification / Explanation of Safety Signal Words | 5 | Protective equipment symbols and the meaning of DANGER, WARNING, CAUTION and NOTICE. |
| Declaration of Conformity | 6 | Multilingual declaration naming the models, directive 94/9/EC, the standards used and the February 2006 date. |
Key Specifications and Data
| Item | Value | Page |
|---|---|---|
| ATEX marking | II 3 GD c IIB 71° C X | 2 |
| Equipment group / category | Group II (non-mine), Category 3 | 4 |
| Gas group | IIB (covers Group A as well) | 4 |
| Maximum surface temperature | 71°C at 21°C ambient; motor at free speed, 90 psig (6.2 bar / 620 kPa) inlet | 3 |
| Required resistance to earth | Less than 10000 Ohms | 3 |
| Maximum air pressure | Rated pressure marked on the starter serial number plate | 3 |
| Excluded gases | Group C gases (acetylene, carbon disulfide, hydrogen), hydrogen sulfide, ethylene oxide, carbon monoxide | 3 |
| Applications | Starting Solar turbines, or driving their pre/post-lube and wet seal back-up pumps; Solar turbines only | 3 |
| Directive | 94/9/EC (ATEX); Machinery Directive 98/37/EC also cited | 4 |
| Standards applied | EN 13463-1, EN 13463-5, EN 1127-1, EN 50014 | 6 |
| Rebuild interval, TS14xx, TS725 and ST9xx models | 4000 start cycles | 3 |
| Rebuild interval, 92RMG10 and 150RMG14C | 1000 start cycles | 3 |
| Serial number range in declaration | SPO6B onward | 6 |
Recommended complete-rebuild interval (gearing, bearings, etc.) for ATEX models
| Solar number | Model | Interval |
|---|---|---|
| 1070744-1 | 201RM16/VRM-172 | 2000 start cycles |
| 1064469-1 | 92RMG10 | 1000 start cycles |
| 1064470-1 | 150RMG14C | 1000 start cycles |
| 1071549-100 | 201RM21 | 2000 start cycles |
| 1065986-100 / -200 / -300 / -400 | TS1425 / TS1499 / TS1435 / TS1450 | 4000 start cycles |
| 1070272-1 | MVA017B/VSM-5842 | 2000 start cycles |
| 1070270-100 | SS1600/1329BA | 2000 start cycles |
| 1070745-200 | TS725GBBE-LE | 4000 start cycles |
| 1070745-100 | TS725GBDE-LE | 4000 start cycles |
| 1065986-11 | ST925G-RC350 | 4000 start cycles |
| 1065986-15 | ST999G-RC350 | 4000 start cycles |
| 1065986-8 | ST935G-RC350 | 4000 start cycles |
| 1065986-17 | ST950GS-RC350 | 4000 start cycles |
Models Covered
Model codes as printed in the document. Linked codes go to the matching Ingersoll Rand starter in our catalog.
ST950GS-RC350 ST925G-RC350 ST935G-RC350 ST999G-RC350 TS725GBBE-LE TS725GBDE-LE TS1425 TS1435 TS1450 TS1499 SS1600/1329BA 201RM16/VRM-172 201RM21 150RMG14C 92RMG10 MVA017B/VSM-5842
Frequently Asked Questions
What does the ATEX marking II 3 GD c IIB 71°C X mean on these starter motors?
Per the manual: Group II non-mine equipment, Category 3, evaluated for gas (G) and dust (D) atmospheres, protection by constructional safety (c), gas group IIB, a 71°C maximum surface temperature, and X for special conditions that must be followed.
How often should an ATEX starter motor for a Solar turbine be rebuilt?
The manual recommends a complete rebuild every 1000, 2000 or 4000 start cycles depending on the model; for example, the TS1425 and ST925G-RC350 are listed at 4000 start cycles.
What surface temperature was measured on these starter motors?
A maximum of 71°C at 21°C ambient, with the motor at free speed on 90 psig (6.2 bar) inlet air.
Can these ATEX starters be used on equipment other than Solar turbines?
No. The document states the ATEX designation applies only to use on Solar turbines and the product is not for non-Solar applications.
What grounding is required for these starter motors?
The manual requires the motor to be grounded at all times with a resistance to earth below 10000 Ohms to avoid electrostatic discharge.
Need the parts or the starter in this document? Send the model number from your starter's plate and we will confirm the right Ingersoll Rand part or replacement.
Source: Ingersoll Rand, No. 10550663, Edition 2, February 2006. Summary and tables prepared by AirStartersDirect.com, an authorized Ingersoll Rand air starter distributor; the PDF is the authoritative version. Page numbers refer to the PDF file. Reviewed October 2026.
Turbine Air Starter Category Links
Industrial duty air starter for engines 5 to 60 liters (Diesel). Commonly used in marine, trucking, transit, and oil & gas applications.